Sign In | Join Free | My components-electronic.com
China Knkong Electric Co.,Ltd logo
Knkong Electric Co.,Ltd
Knkong Electric Co.,Ltd
Active Member

5 Years

Home > Gas Insulated Switchgear >

12KV 630A Gas Insulated Switchgear RMU Ring Main Unit

Knkong Electric Co.,Ltd
Contact Now

12KV 630A Gas Insulated Switchgear RMU Ring Main Unit

Brand Name : Knkong

Model Number : SF6 GIS HXGN15-12

Certification : IEC ISO

Place of Origin : China

MOQ : 1

Payment Terms : L/C, T/T

Supply Ability : 100 Unit per month

Delivery Time : 30 days

Packaging Details : Standard export packaging

Rating Voltage : 12KV

Rating Current : 630A

Rating Frequency : 50/60Hz

Standards : GB ISO IEC

OEM/ODM : Inquiry by email

Manufactory : KNKONG

Contact Now

GB ISO 36KV Gas Insulated Switchgear Medium Voltage Ring Main Unit

Product Introduction

General

This RMU switchgear using SF6 as an arc extinguishing medium with double open contacts, 3 working-position and rotating contact which placed in an epoxy resin shell of a reinforced structure. Each gas box must pass helium leak detection before being filled with 0.045Mpa SF6 (Inspect any leakage to ensure can be installed vertically or horizontally). The classic installation is "horizontal", that is, install steel partitions between the cable compartment and the busbar compartment. That makes the interval between the busbar and the cable joint the most stringent safety requirements.

Standard

  • ISO 780-1997,MOD
  • IEC 62271-102:2002,MOD
  • IEC 60265-1:1998,MOD
  • IEC 60298:1990
  • IEC 60529:1989
  • IEC 507:1991
  • IEC 60694:1996
  • IEC 60420:1990

Technical Data

No. Item Unit Parameter
1 Rated voltage kV 12 24 36
2 Rated frequency Hz 50/60
3 Rated current A 630(1250*)
4

1min Power frequency

withstand voltage

wet kV 38 50 70
dry kV 48 60 85
5 Lightning impulse withstand voltage kV 75 125/150 170
6 Rated short circuit breaking current (peak) kA 80 63 63
7 Rated active load and close circuit breaking current A 63 50 50
8 Rated transferring current A 1700 1200 1200
9 Rated short circuit making a current (peak) kA 80 63 63
10 Rated cable(line) charging breaking current A

50 and 10

50/10

11 Cable charge breaking current in earthing fault A 20 20 20
12 Rated withstand current (peak) kA 80 63 63
13 Short-time withstand current (2s) kA 25 20 20
14 Mechanism life times 5000 2000 2000

Note: For short circuit breaking and the peak current is based on Fuse plus combination

12KV 630A Gas Insulated Switchgear RMU Ring Main Unit12KV 630A Gas Insulated Switchgear RMU Ring Main Unit12KV 630A Gas Insulated Switchgear RMU Ring Main Unit12KV 630A Gas Insulated Switchgear RMU Ring Main Unit


Product Tags:

12KV 630A Gas Insulated Switchgear

      

RMU Ring Main Unit

      

Arc Extinguishing Ring Main Unit

      
Buy cheap 12KV 630A Gas Insulated Switchgear RMU Ring Main Unit product

12KV 630A Gas Insulated Switchgear RMU Ring Main Unit Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Knkong Electric Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)